1. Home
  2. Exin
  3. CDCS Exam Syllabus

Exin CDCS Exam Syllabus

Start Free CDCS Exam Practice After Reviewing the Topics

Before starting your CDCS exam preparation, it is recommended to review the complete Exin EPI Certified Data Centre Specialist exam syllabus and carefully go through the exam objectives listed below. Once you understand the exam structure and objectives, you should practice using our free CDCS questions. We also provide premium CDCS practice test, fully updated according to the latest exam objectives, to help you accurately assess your preparedness for the actual exam.

Vendor
CDCS
Exam Code
120
Total Questions
11
Total Exam Domains

START FREE CDCS EXAM PRACTICE

NO SIGNUP REQUIRED  •  100% FREE TO START

CDCS EXAM QUESTIONS

Exin CDCS Exam Objectives

Section 1: Data Centre Design/Life Cycle Overview
Weight:
-
  •  Overview of the phases of a data centre life cycle
  •  Planning, re-alignment and continuous improvement
Section 2: Standards and Rating Level Definitions
Weight:
-
  •  Rating level history
  •  Standards and guidelines compared (TIA-942, ISO 22237, EN 50600, UTI)
  •  Rating level definitions
  •  Redundancy options (N+1), 2N, 2(N+1)
  •  Concurrent Maintainability/Compartmentalisation
  •  Example configurations
  •  Substation and feed requirements
  •  Maintenance options
  •  Operational processes guidelines/standards
  •  Skill development
Section 3: Building Considerations
Weight:
-
  •  Building location considerations
  •  Floor and hanging loads requirements
  •  Fire rating for walls and glass
  •  Blast protection
  •  Bullet proofing
  •  Forced entry protection
Section 4: Advanced Raised Floor & Suspended Ceiling
Weight:
-
  •  Raised floor installation guidelines
  •  Techniques to install a proper and leveled raised access floor
  •  Common mistakes
  •  Choosing the right tiles and their locations
  •  Seismic-mitigating floor constructions
  •  Choosing the correct suspended ceiling
Section 5: Advanced Power
Weight:
-
 Power infrastructure layout;
  •  Formulas which you should know for the data centre
  •  Single Line Electrical diagrams; how to read to ensure key components are present for protection
  •  Over current protection devices (MCB/MCCB/VCB/ACB/Fuses) definitions and what to use where
  •  Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/RCBO), definitions and what to use where
  •  Sizing of protective components
  •  Lightning strikes and surge protection devices (TVSS/SPD), how they operate, where to use and how to install
  •  Power cabling and cable run considerations
  •  PDU/DB setup and minimum requirements
 Generators;
  •  Generator types: Standy/Prime/Continuous
  •  Component make up and functions
  •  Fuel storage and calculation
  •  Paralleling of gen-sets
  •  Generator room/area requirements
 UPS Systems;
  •  Required specifications for UPS systems
  •  How to read data sheets and select the correct UPS
  •  Requirements for parallel configurations and avoid pitfalls such as single point of failures
  •  How parallel installation should be done, classic mistakes made by installers and how to avoid these
 Harmonic Filters;
  •  Active/Passive filters and their application
 Battery Banks;
  •  Battery bank terminology
  •  Designing battery banks, how to calculate, and double check the battery bank to be installed
  •  Battery charging pitfalls and ensuring the right charger is being installed and used
  •  Using parallel battery banks; how to properly install them, limitations and risks when using batteries in parallel
  •  How to test batteries correctly and make decisions on cell/block or string replacement
  •  Battery casing choices; ABS, V0, V1, V2
  •  Alternative energy storage; flywheel, re-usable cell, compressed air UPS, etc.
Section 6: Advanced Electro Magnetic Fields
Weight:
-
  •  Sources of EMF
  •  Difference between single, three phase and bus-bar EMF
  •  Options available to measure EMF and how to interpret the results from single-axes and composite measurements
  •  Guidance on safe distance for equipment and humans
  •  Calculation of EMF attenuation factor for shielding material permeability and saturation factors
Section 7: Advanced Cooling
Weight:
-
  • Important definitions; dry-bulb, wet-bulb, dew-point, RH, sensible
  •  and latent heat
  •  Psychometric chart and ASHRAE recommendations
  •  Environmental class definitions and thermal specifications
  •  Temperature/humidity measurements guideline
  •  Heat dissipation methods
  •  Altitude impact on temperature intake to ICT equipment
  •  Floor plan setup for effective cooling
  •  Differences in tile surface and supporting structure and the air-flow performance impact
  •  Rack door construction and the flow performance impact
  •  Equipment Delta-T and its impact
  •  Optimising airflow
  •  Thermal units conversions
  •  Calculations for air volume displacement (CFM/CMH)
  •  Cooling capacity calculations
  •  Air-conditioning selection
  •  De- / humidifying options
  •  Air conditioning efficiency
  •  SHR impact on cost saving
  •  Efficiency indicator
  •  New cooling principles and techniques (Liquid, liquid submerged, VSD/VFD/EC Fans/VRF/water- and air side economisers)
  •  Redundancy guidelines for air-conditioners avoiding classic misconceptions and mistakes for meeting ANSI/TIA-942 compliant designs
  •  Installation requirements
  •  Connections to fire panel and EPO
  •  Commissioning of air conditioners
  •  Set points and calibration
  •  CFD (Computational Fluid Dynamics)
Section 8: Advanced Fire Protection
Weight:
-
  • The fire triangle and elements to stop a fire
  •  Detection systems in detail (VESDA, VIEW, smoke sensors)
  •  Considerations for installation of sensors
  •  Proper testing of smoke sensors
  •  Water based systems i.e. deluge, wet-pipe, dry-pipe, pre-action and why most of them don't work and how to detect this
  •  Details on Inert and Halocarbon systems and how to select the correct system for your data centre
  •  How to calculate the gas content ensuring the appropriate level is installed to suppress the fire, including safety considerations
  •  Other requirements for gas systems such as release times, hold times, pipe install requirements and other important factors
  •  Requirements for the fire detection panel
  •  Installation verification, methods, what to check and how
  •  New advanced fire suppression technologies 
Section 9: Design and Install Scalable Networking Cabling System
Weight:
-
  •  ANSI/TIA942 cabling structure topology
  •  Copper and fiber cabling
  •  ToR, EoR Design
  •  Intelligent patching systems
  •  Installation best practice such as routing, bending radius, separation from power, containment fill ratio, fiber link loss calculator, bonding and grounding requirement
  •  Standard for telecommunications labeling and administration
Section 10: Environmental Specications and Contamination Control
Weight:
-
  •  Acoustic noise effects, regulations, specifications and limits
  •  Data centre contaminations and classifications
  •  Measurements, standards and limits
  •  Preventive measures and avoidance
Section 11: Data Centre Efficiency
Weight:
-
  •  Business drivers to go Green
  •  Sustainability versus high-availability
  •  Green standards and guidelines
  •  Power Usage Eectiveness (PUE), values, classes, considerations and improvements
  •  Open Compute Project (OCP)
  •  Savings on cooling infrastructure
  •  Savings on light infrastructure
Info