Before starting your CDCP exam preparation, it is recommended to review the complete Exin Certified Data Centre Professional Exam syllabus and carefully go through the exam objectives listed below. Once you understand the exam structure and objectives, you should practice using our free CDCP questions. We also provide premium CDCP practice test, fully updated according to the latest exam objectives, to help you accurately assess your preparedness for the actual exam.

Vendor
CDCP
Exam Code
88
Total Questions
14
Total Exam Domains

START FREE CDCP EXAM PRACTICE

NO SIGNUP REQUIRED  •  100% FREE TO START

CDCP EXAM QUESTIONS

Exin CDCP Exam Objectives

Section 1: Data Centre Location, Building and Construction
Weight:
-
  • Selecting appropriate sites and buildings and how to avoid pitfalls
  •  Various components of an effective data centre and supporting facilities setup
Section 2: Raised Floor/Suspended Ceiling
Weight:
-
  • Uniform, concentrated and rolling load definitions 
  • Applicable standards
  • Raised floor guidelines
  • Signal Reference Grid, grounding of racks
  • Disability act and regulations
  • Suspended ceiling usage and requirements
Section 3: Light
Weight:
-
  • Standards
  • Light fixture types and placement
  • Emergency lighting, Emergency Power Supply (EPS)
Section 4: Power Infrastructure
Weight:
-
  • Power infrastructure layout from generation to rack level
  •  ATS and STS systems
  •  Redundancy levels and techniques
  •  Three-phase and single-phase usage
  •  Power distribution options within the computer room
  •  Power cabling versus bus bar trunking
  •  Bonding versus grounding
  •  Common Mode Noise and isolation transformers
  •  Distribution boards, form factors and IP-protection grades
  •  Power quality guidelines
  •  Real power versus apparent power
  •  How to size and calculate load in the data centre
  •  Generators
  •  Static and dynamic UPS systems, selection criteria,
  •  how they operate and energy efficiency option
  •  Battery types, correct selection and testing
  •  Thermo-graphics
  •  Renewable Energy Factor (REF)
Section 5: Electro Magnetic Fields
Weight:
-
  • Electrical fields and magnetic fields definitions and units of measurements
  • Sources of EMF
  • Effects of EMF on human health and equipment
  • (H)EMP
  • Standards
  • EMF shielding solutions
Section 6: Equipment Racks
Weight:
-
  • Rack standards, properties and selection criteria
  • Security considerations
  • Power rail/strip options
Section 7: Cooling Infrastructure
Weight:
-
  •  Temperature and humidity recommendations
  •  Cooling measurement units and conversion rates
  •  Sensible and latent heat definitions
  •  Differences between comfort and precision cooling
  • Overview of different air conditioner technologies
  •  Raised floor versus non-raised floor cooling
  •  Placement of air conditioner units and limitations to be observed
  •  Supplemental cooling options
  •  Cold aisle/hot aisle containment
  •  Liquid immersion cooling
  •  Cooling concepts: Seasonal Thermal Energy Storage (STER)
Section 8: Water Supply
Weight:
-
  • Importance of water supply and application areas
  • Backup water supply techniques
Section 9: Designing a Scalable Network Infrastructure
Weight:
-
  •  The importance of a Structured Cabling System
  •  Planning considerations
  •  Copper and Fiber cable technology and standards
  •  ANSI/TIA-942 Cabling hierarchy and recommendations
  •  Testing and verification
  •  Network redundancy
  •  Building-to-building connectivity
  •  Network monitoring system requirements
Section 10: Fire Safety/Protection
Weight:
-
  • Standards for fire suppression
  • Detection systems
  • Various total flooding fire suppression techniques and systems, their benefits and disadvantages
  • Handheld extinguishers
  • Signage and safety
  • Regulatory requirements and best practices
Section 11: Physical Security and Safety
Weight:
-
  • Physical security considerations
  • Physical safety considerations
Section 12: Auxiliary Systems
Weight:
-
  • Data centre monitoring requirements
  • EMS, BMS and DCIM
  • Water leak detection systems
  • Alarm notification
Section 13: The Data Centre, its Importance and Causes for Downtime
Weight:
-
Section 14: Data Centre Standards and Best Practices